Benvenuti sulla nostra nuova piattaforma ICP DAS
Che sostituisce industrialtech.it

WP-5147-OD-EN CR ICP DAS new

WP-5147-OD-EN CR ICP DAS

WP-5147-OD-EN CR ICP DAS

WP-5147-OD-EN CR

ISaGRAF based WinPAC-5000 with Audio (English Version of OS) (RoHS)

Price

€ 867,46

(VAT excluded)

€ 1.058,30(VAT included)

Prezzo di 1 pz. iva (22%) inclusa: € 1.058,30

Availability: Not Available

SKU: 93274

Model: WP-5147-OD-EN CR

Need Help?


  • PXA270, 520 MHz CPU
  • Windows CE .NET 5.0 Core
  • Embedded ISaGRAF Ver.3 SoftLogic (IEC 61131-3)
  • Support eLogger HMI
  • Hard Real-Time Capability
  • 64-bit Hardware Serial Number for Software Protection
  • Microphone-In and Earphone-out
  • I/O Expansion Bus
  • VGA Port Output
  • Dual 10/100M Ethernet Ports
  • 3 Serial Ports (RS-232/485)
  • Operating Temperature: -25 ~ +75 °C

INTRODUCTION

The ISaGRAF WinPAC-5000 Series (WP-5147 / WP-5147-OD) is equipped with a PXA270 CPU (520 MHz) running a Windows CE .NET 5.0 operating system, a variety of Input/Output ports (VGA, USB, Ethernet, RS-232/485) and an I/O expansion bus for one XW-Board. The benefits of running Windows CE 5.0 on a WinPAC device include hard real-time capability, small core size, fast boot speed, interrupt handling at a deeper level and achievable deterministic control. WinPAC devices are also capable of running ISaGRAF and PC-based control software, such as Visual Basic .NET, Visual C#, etc., providing all of the best features of both traditional PLCs and Windows capable PCs.

SPECIFICATIONS

System Software
OS: Windows CE 5.0 Core
.Net Compact Framework: 3.5
Embedded Service: FTP Server, Web Server
Multilanguage Support: English, German, French, Spanish, Russian, Italian, Korean, Simplified Chinese, Traditional Chinese
 
Development Software
ISaGRAF Software: ISaGRAF Ver.3: IEC 61131-3 standard
          Languages: LD, ST, FBD, SFC, IL & FC
          Max. Code Size: 1 MB
          Scan Time:  3 ~ 15 ms for normal program

 15 ~ 50 ms for complex or large program
 
Non-ISaGRAF: Options: MS eVC++ 4.0 or VS.NET 2005/2008 (VB.NET, C#.NET)
 
CPU Module  
CPU: PXA270, 520 MHz
SDRAM: 128 MB
Flash: 64 MB
EEPROM: 16 KB
Expansion Flash Memory: microSD socket with one microSD card (support up to 32 GB)
Battery Backup SRAM: Require one XW608, 512 KB (for retain variables)
RTC (Real Time Clock): Provide second, minute, hour, date, day of week, month, year
64-bit Hardware Serial Number: Yes, for Software Copy Protection
Dual Watchdog Timers: Yes
LED Indicator: 1 LED for Power and Running
         2 LEDs for user programmable
 
Rotary Switch: Yes (0 ~ 9)
 
VGA & Communication Ports
VGA: Yes ; 640 x 480, 800 x 600
Ethernet: RJ-45 x 2, 10/100 Base-TX (Auto-negotiating, Auto MDI/MDI-X, LED indicators)
USB 1.1 (client): 1
USB 1.1 (host): 1
Audio: Microphone-In and Earphone-Out
COM1: RS-232 (RxD, TxD and GND); Non-isolated
COM2: RS-485 (Data+, Data -); 2500 VDC isolated
COM3: RS-232 (RxD, TxD and GND); Non-isolated
 
I/O Expansion  
I/O Expansion Bus: Yes; to mount one optional XW-Board . 
No supporting XW5xx board (i.e. XW506, XW507, XW508, XW509, XW511i, XW514)
 
Mechanical  
Dimensions (W x L x H): 91 mm x 132 mm x 52 mm
Installation: DIN-Rail Mounting
 
Environmental  
Operating Temperature: -25 ~ +75 °C
Storage Temperature: -30 ~ +80 °C
Ambient Relative Humidity: 10 ~ 90 % RH (non-condensing )
 
Power  
Input Range: +10 ~ +30 VDC
Isolation: 1 kV
Consumption: 6 W
 
Protocols (Note that certain protocols require optional devices)
NET ID: 1 ~ 255, User-assigned by software
 
Modbus TCP/IP Master: Link to a max. of 100 devices that support the Standard Modbus TCP/IP Slave protocol. Support one or more tGW-700 series gateway (Modbus TCP to Modbus RTU/ASCII) to expand many Modbus RTU / ASCII master ports to connect many Modbus RTU / ASCII slave devices.
 
Modbus RTU/ASCII Master: Support Multi-port. A max. of 10 ports
 
Modbus RTU Slave: A max. of 5 ports
 
Modbus TCP/IP Slave: Two Ethernet ports, LAN1 & LAN2, support total up to 32 connections. If one of the Ethernet port malfunctions, the other one can still be used to connect to the PC/HMI.
 
Web HMI Protocol: Ethernet Ports for connecting a PC running Internet Explorer.
 
User-defined Protocol: Custom protocols can be applied at COM1 ~ COM3 using Serial communication function blocks.
 
I-7000 & I-87K RS-485 Remote I/O: COM2 supports I-7000 I/O modules, I-87K base + I-87K Serial I/O boards, or RU-87Pn + I-87K High Profile I/O boards as remote I/O. A max. of 255 I-7000/87K remote I/O modules can connect to one PAC.
 
M-7000 Series Modbus I/O: A max. of 10 RS-485 ports can support M-7000 I/O. Each port can connect up to 32 M-7000 Modules.
 
Modbus TCP/IP I/O: LAN2 supports ICP DAS Ethernet I/O: I-8KE4-MTCP and I-8KE8-MTCP. If LAN2 malfunctions, it will automatically switch to LAN1 to continuously work. (The IP address for LAN1 and LAN2 should be set in the same IP domain) (FAQ-042)
 
Send Email: Provide functions to send email with a single attached file via the Ethernet port.
 
Ebus: LAN2 can be used to exchange data between ICP DAS ISaGRAF Ethernet PACs via the Ethernet port.
 
UDP Server & UDP Client: Exchange Message & Auto-report: LAN1 or LAN2 supports the UDP Server and UDP Client protocols allowing messages to be sent/received to/from a PC/HMI or other device. For example, data can be automatically reported to the InduSoft’s RXTX driver.
 
TCP Client: Exchange Message & Auto-report: LAN1 or LAN2 supports the TCP Client protocol allowing messages to be sent/received to/from a PC/HMI or other device that supports the TCP server protocol. Ex: automatically report data to InduSoft's RXTX driver, or to connect a location camera.
 
eLogger HMI: Provide support for the eLogger HMI. The user can design the HMI screen using the eLogger on the PC and then download it to the PAC to display the HMI on the PAC. (FAQ-115)
 
SQL Client: Support for the SQL Client function that allows data to be written (or read from) a Microsoft SQL Server (2000 SP3, 2005, 2008).
 
CAN/CANopen: COM1, COM3 can connect to one I-7530 (converter: RS-232 to CAN) to support CAN/CANopen devices and sensors. One WP-5xx7 supports a max. of 10 RS-232 ports to connect a max. of 10 I-7530. (FAQ-086)
 
FTP Client: Enable the FTP Client to upload files from the PAC to a remote FTP server on a PC. (FAQ-151)