Benvenuti sulla nostra nuova piattaforma ICP DAS
Che sostituisce industrialtech.it

PM-3114-160 ICP DAS new

PM-3114-160 ICP DAS

PM-3114-160 ICP DAS

PM-3114-160

Modbus RTU, 4 loops single-phase power meter (100 A) RS-485 Interface

Price

€ 361,02

(VAT excluded)

€ 440,44(VAT included)

Prezzo di 1 pz. iva (22%) inclusa: € 440,44

Availability: Not Available

SKU: 93046

Model: PM-3114-160

Need Help?


  • True RMS Power Measurements
  • Energy Analysis for 1P2W, 1P4W
  • Current Measurements Up to 200 A with Different CT Ratio
  • Voltage Measurements Up to 300 V
  • Clip-on CT for Easy Installation
  • W Accuracy Better than 1% (PF=1)
  • Supports RS-485, Ethernet or CAN bus Interface
  • Supports Modbus RTU, Modbus TCP or CANopen Protocol
  • Supports 2 Power Relay Output (Form A)

Introduction

ICP DAS brings the most powerful, cost-effective, advanced Smart Power Meters PM-3000 series that gives you access to real-time electric usage for single-phase power measurement. With its high accuracy (<1%, PF=1 ), the PM-3000 series can be applied to both low voltage primary side and/or medium/high voltage secondary side and enables the users to obtain reliable and accurate energy consumption readings from the monitored equipments in real time under operation. These compact size and cost-effective power meters are equipped with revolutionary wired clip-on CT (various types, support input current up to 200 A). It operates over a wide input voltages range 10 ~ 300 VAC which allows worldwide compatibility. And with 2 channels relay outputs, it can be linked with sirens or lightings for alarm messages. It also supports Modbus RTU, Modbus TCP or CAN bus protocols for easy integration.

Specifications

AC Power Measurement
Wiring: 1P4W-4CT 
Input Voltage: 10 ~ 300 V
Input Current: CT Φ10 mm (60 A); CTΦ16 mm (100 A); CTΦ24 mm (200 A)
Input Frequency: 50/60 Hz
W Accuracy: Better than 1% (PF=1)
Starting Current: >0.03A ( 60A ), >0.05A (100A ), >0.09A( 200A )
Power Parameter Measurement: True RMS voltage (Vrms), True RMS current (Irms), Active Power (kW), Active Energy (kWh), Apparent Power (kVA), Apparent Energy (kVAh), Reactive Power (kVAR), Reactive Energy (kVARh), Power Factor (PF)
Data Update Rate: 1 Second
 
Communication
RS-485 Protocol: Modbus-RTU
         Baud rate: 9600,19200 (default), 38400, 115200; DIP Switch Selectable
         Data format: N,8,1 
         Isolation: 2500 VDC
 
Alarm Output
Power Relay: Form A (Normal Open) x 2; Relay Contact Voltage Range: 5 A @ 250 VAC (47 ~ 63Hz), 5 A @ 30 VDC
 
Power
Input Range: +10 ~ 30 VDC
Power Consumption: 2 W
 
Mechanical
Casing: Plastic (Flammability UL 94V-0)
Dimensions (W x L x H): 127 mm x 105 mm x 33 mm
Module Installation: DIN-Rail Mounting
CT Installation: Clip-On
 
Environment
Operating Temperature: -10 ~ +70 °C
Storage Temperature: -25 ~ +80 °C
Ambient Relative Humidity: 10% ~ 90% RH, Non-condensing

Disclaimer