Benvenuti sulla nostra nuova piattaforma ICP DAS
Che sostituisce industrialtech.it

PM-2133-240-CAN ICP DAS new

PM-2133-240-CAN ICP DAS

PM-2133-240-CAN ICP DAS

PM-2133-240-CAN

3 Phase Compact Smart Meter /CT:3pcs, 24mm(0-200A)/English /CAN bus , Modbus RTU

Price

€ 652,78

(VAT excluded)

€ 796,39(VAT included)

Prezzo di 1 pz. iva (22%) inclusa: € 796,39

Availability: Not Available

SKU: 4876

Model: PM-2133-240-CAN

Need Help?


  • True RMS energy and power parameters measurement in compact size
  • Easy wiring for on-line installation
  • RS-485 communication supported Modbus protocol
  • Compatible with CAN specification 2.0B
  • Support CAN baud-rate: 125 k, 250 k, 500 k, 1 M bps
  • Wh accuracy better than 1% (PF=1)
  • With wired clip-on CT (various types support input current up to 200A)
  • LED pulse output

It's always difficult but crucial to the supervisors to figure out how much energy is consuming. ICP DAS brings the most powerful, cost effective, advanced Compact Power Meters, PM-213X series, to the markets.

With its high accuracy (1%, PF=1), the PM-213x series products can be applied both on low voltage primary side and/or medium/high voltage secondary side and enable the users to obtain in real time the reliable and accurate energy consumption readings from the monitored equipments while in operation. These compact size and cost effective Power Meters are equipped with revolutionary wired clip-on CT (various types support input current up to 200A) and standard Modbus communication RS-485 protocol for easy deployment. It works with input voltages ranging 10V ~ 500V, supporting a wide range of applications.

ICP DAS offers PM-213X family in a full range of Single-phase and Three-phase compact power meters for power monitoring. The products offer a rich feature set combined with easy-to-integrate communications.

Specifications

Input Voltage: 10 - 500 V
Input Current: CT Φ10 mm (60 A), CT Φ16 mm (100 A), CT Φ24 mm (200 A)
Aux Power: DC 10 - 30 V
Starting I: <0.025A
Frequency: 60/50 Hz
Wiring diagram: Auto or manual stting 1P2W-1CT, 1P3W-2CT, 3P3W-2CT, 3P3W-3CT, 3P4W
Power Parameters Measures: 
                               VA, VB, VC, Vave
                               I A, I B,I C, I ave
                               kWA, kWB, kWC, kWtot
                               kVAA, kVAB, kVAC, kVAtot
                               kvarA, kvarB, kvarC, kvartot
                               PFA, PFB, PFC, PFtot
                               kWhA , kWhB, kWhC, kWhtot
                               kVAhA , kVAhB, kVAhC, kVAhtot
                               kvarhA , kvarhB, kvarhC, kvarhtot
Communication:
                  Protocol:
                        Modbus-RTU
                            RS485, half duplex isolated
                            Baud Rate:9600, 19200(default), 38400
                  Protocol:
                        CAN bus
                            Baud Rate:125 k(default),250 k,500 k,1000 k
                   Protocol:
                        CANopen
                            Baud Rate: 10 k,20 k,50 k 125 k(default),250 k,500 k,800 k,1000 k
kWh Accuracy: 1%(PF=1)
Dimension: 78(L) × 35(W) × 99(H) mm
Operating Temperature: -10 °C ~ 70 °C
Installation: Rail-mounted

Disclaimer