WISE-5800
User-defined I/O & Data Logger Module
- Built-in IF-THEN-ELSE rule enigne for logic operation
- Built-in Web Server for IF-THEN-ELSE rule setting
- No more programming. Click and get done!
- Support I/O, Counter, Timer, Email, Recipe operations
- Data logger and data files send back function supported
- Modbus TCP/RTU Protocol for SCADA Software Seamless
- Integration
- Support XW-Board
- Support I-7000 Remote I/O Modules(Up to 16)
- Support Modbus RTU Slave Devices(Up to 4)
- SNTP Time Synchronization Supported
WISE (Web Inside, Smart Engine) is a product series developed by ICP DAS that functions as control units for use in remote logic control and monitoring in various industrial applications. WISE offers a user-friendly and intuitive web site interface that allows users to implement IF-THEN-ELSE control logic on controllers just a few clicks away; no programming is required. With its powerful and easy-to-use features, it will minimize the learning curve, shorten time to market and dramatically reduce the labor and cost spent on system development. WISE-5800 supports an I/O expansion bus to implement various I/O functions such as D/I, D/O, A/D and D/A according to the XW-Board. In addition, WISE-5800 also support ICP DAS I-7000 remote I/O modules and Modbus RTU slave devices. Based on the variety I/O module of I-7000 and the connection ability with Modbus RTU slave devices, WISE-5800 can provide user more flexibility in application field. WISE-5800 supports Modbus TCP/RTU protocol to make seamless integration with SCADA software available. It include all advantages which WISE series controllers can provide. In addition, WISE-5800 provide data logger function with microSD card, it can record I/O channel value by event trigger or regular time period. The data files can be sent back by Email or FTP. All setting can be completed through browser.
System
CP: 16-bit CPU
SRA: 768KB
Flash Memor: 512KB
EEPRO: 16 KB
NVRA: 31 Bytes
microSD Expansio: Yes, can support 1 or 2 GB microSD
RTC (Real Time Clock): Provide second, minute, hour, date of week, month and year
Watchdog: Yes
Communication
Ethernet: RJ-45 x 1, 10/100 Base-TX (Auto-negotiating, Auto MDI/MDI-X)
COM 1: RS-232 (TxD, RxD, RTS, CTS, GND), non-isolated, Speed: 115200 bps max.
COM 2: RS-485 (D2+, D2-), self-tuner ASIC inside, non-isolated, Speed: 115200 bps max.
LED Indicators
System LED: Yes (Red)
Ethernet Link LED: Yes (Green: Ethernet link detected, Flashing Green: Ethernet packet received)
Hardware Expansion
I/O Expansion Bus: Yes
Power Requirements
Protection Power Reverse Polarity: Protection
Frame Ground Yes: (for ESD Protection)
Input Range: 12 ~ 48 VDC
Redundant Power Input: Yes
Power Consumption: 2.0 W
Mechanical
Dimensions (W x H x D): 91 mm x 132 mm x 52 mm
Installation: DIN-Rail
Environmental
Operating Temperature: -25 °C ~ +75 °C
Storage Temperature: -30 °C ~ +80 °C
Humidity: 10 ~ 90% RH, non-condensing
Power
Protection: Power reverse polarity protection
Frame Ground: Yes (for ESD Protection)
Input Range: +12 ~ +48 VDC
Redundant Power Input: Yes
Power Consumption: 2.0 W
Functions
Rule Configuration Website: Access Web server on WISE controllers to edit and upload logic rules through web browser.
36 IF-THEN-ELSE Logic Rules:
3 IF conditions with AND or OR operators
3 THEN actions and 3 ELSE actions
48 Internal Registers: Hold temporary variables and read/write data via Modbus/TCP address.
12 Timers: Delay / Timing functions.
12 Schedules: Setup prescheduled routine tasks.
12 Emails: Send Email messages to pre-set Email receivers.
12 CGI Commands: Send pre-set CGI commands.
12 Recipes: Set up THEN/ELSE action groups.
Data Logger: Set up the Data Logger configuration, include the data record format, and data file sending operation.
Modbus TCP/RTU Protocol: Real time control and monitoring I/O channels and system status of controllers via SCADA software.
IF Conditions
DI Channel: ON、OFF、ON to OFF、OFF to ON、Change
AI Channel - Internal Register: =、>、<、>=、<=(value)
DI Counter: =、>、<、>=、<=(value)、Change
Timer: Timeout、Not Timeout
Schedule: In Range、Out of Range
Rule Status: Enable、Disable
THEN / ELSE Actions
DO Channel: ON、OFF、Pulse Output (Just for XW-Board)
AO Channel - Internal Register: Change the value
DI Counter: Reset
Timer: Start、Reset
Schedule: Enable、Disable
Email - CGI Commands: Send
Recipe: Execute
Data Logger: Start、Stop、One-Time Log
Rule Status: Enable、Disable