Benvenuti sulla nostra nuova piattaforma ICP DAS
Che sostituisce industrialtech.it

WISE-7167 ICP DAS

WISE-7167 ICP DAS

WISE-7167

8-Channel Power Relay Output WISE PoE Controller (RoHS)

Price

€ 283,73

(VAT excluded)

€ 346,15(VAT included)

Prezzo di 1 pz. iva (22%) inclusa: € 346,15

Availability: Not Available

SKU: 4449

Model: WISE-7167

Need Help?


  • Built-in Web Server for IF-THEN-ELSE rule setting
  • Built-in IF-THEN-ELSE rule enigne for logic operation
  • No more programming. Just click and get done!
  • Support IO, Counter, Timer, Email operations
  • Modbus/TCP Protocol for SCADA Software Seamless Integration
  • IEEE 802.3af-compliant Power over Ethernet (PoE)
  • 10/100 Base-TX Ethernet
  • 2-way Isolation/ESD Protection
  • DO Type: 8 Power Relay (Form A)

WISE (Web Inside, Smart Engine) is a product series developed by ICP DAS that functions as control units for use in remote logic control and monitoring in various industrial applications. WISE offers a user-friendly and intuitive web site interface that allows users to implement IF-THEN-ELSE control logic on controllers just a few clicks away; no programming is required. With its powerful and easy-to-use features, it will minimize the learning curve, shorten time to market and dramatically reduce the labor and cost spent on system development. WISE-7167 follows IEEE 802.3af-compliant (classification, Class 1) Power over Ethernet (PoE) specification. It allows receiving power from PoE enabled network by Ethernet pairs (Category 5 Ethernet cable). This feature provides greater flexibility and higher efficiency therefore simplifying systems design, saving space, reducing cables and eliminating the requirement for dedicated electrical outlets. Meanwhile, in case under a non-PoE environment, WISE-7167 will still be able to receive power from auxiliary power sources like AC adapters or battery, etc. This module WISE-7167 supports Modbus/TCP protocol to make seamless integration with SCADA software available. It features 8-channel power relay outputs. Each power relay supports contact rating as 5 A @ 250 VAC or 5 A @ 30 VDC.

Power Relay

Output Channels: 8
Output Type: Power Relay, Form A (SPST N.O.)
Operating Voltage Range: 250 VAC/30 VDC
Max. Load Current: 5.0A/channel at 25 °C
Operate Time: 6 ms (Typical)
Release Time: 3 ms (Typical)
Electrical Life (Resistive Load):
                                VDE:
                                  5A 250 VAC 30,000 ops (10 ops/minute) at 75 °C
                                  5A 30 VDC 70,000 ops (10 ops/minute) at 75 °C
                                UL:
                                  5A 250 VAC/30 VDC 6,000 ops
                                  3A 250 VAC/30 VDC 100,000 ops.
Mechanical Life 20,000,000 ops. at no load (300 ops./minute)

System

CPU: 16-bit CPU
SRAM: 512KB
Flash Memory: 512KB
EEPROM: 16KB
Watchdog: Yes

Communication

PoE Ethernet Port
10/100 Base-TX and automatic MDI/MDI-X

2-Way Isolation

I/O 3000 Vrms

EMS Protection

ESD (IEC 61000-4-2): 4 kV Contact for each terminal
EFT (IEC 61000-4-4): +/-2 kV for Power

LED Indicators

PoE Power PoE: On
L1: System Running
L2: Ethernet Link/Act
L3: Ethernet 10/100 M Speed

Power Requirements

Reverse Polarity Protection: Yes
Powered from Terminal Block: Yes, 12 ~ 48 VDC
Powered from PoE: Yes, IEEE 802.3af, Class1
Consumption: 5.3 W

Mechanical

Dimensions (W x L x D): 72 mm x 123 mm x 35 mm
Installation: DIN-Rail or Wall mounting

Environment

Operating Temperature: -25 °C ~ +75 °C
Storage Temperature: -30 °C ~ +80 °C
Humidity: 10 ~ 90% RH, non-condensing

Functions

Rule Configuration Website: Access Web server on WISE controllers to edit and upload logic rules through web browser.
36 IF-THEN-ELSE Logic Rules: 
        3 IF conditions with AND or OR operators
        3 THEN actions and 3 ELSE actions
48 Internal Registers: Hold temporary variables and read/write data via Modbus/TCP address.
12 Timers: Delay / Timing functions.
12 Emails: Send Email messages to pre-set Email receivers.
12 CGI Commands: Send pre-set CGI commands.
12 Recipes: Set up THEN/ELSE action groups.
8 P2P remote modules: Set up the connection information for the remote WISE modules.
Modbus/TCP Protocol: Real time control and monitoring I/O channels and system status of controllers via SCADA software.

IF Conditions

Internal Register: =、>、<、>=、<=(value)
DO Counter: =、>、<、>=、<=(value)、Change
Timer: Timeout、Not Timeout
P2P: DI、AI、DI counter、DO counter、IR
Rule Status: Enable、Disable

THEN / ELSE Actions

DO Channel: ON、OFF、Pulse Output
Internal Register: Change the value
DO Counter: Reset
Timer: Start、Stop
Email - CGI Commands: Send
Recipe: Execute
P2P: DO(On/Off)、AO、IR
Rule Status: Enable、Disable

Disclaimer