Benvenuti sulla nostra nuova piattaforma ICP DAS
Che sostituisce industrialtech.it

WISE-7144 ICP DAS

WISE-7144 ICP DAS

WISE-7144

8-channel Isolated Sink Type Open Collector Output and 8-channel Isolated Digital Input WISE PoE Controller (RoHS)

Price

€ 259,32

(VAT excluded)

€ 316,37(VAT included)

Prezzo di 1 pz. iva (22%) inclusa: € 316,37

Availability: Not Available

SKU: 4445

Model: WISE-7144

Need Help?


  • Built-in Web Server for IF-THEN-ELSE rule setting
  • Built-in IF-THEN-ELSE rule enigne for logic operation
  • No more programming. Just click and get done!
  • Support IO, Counter, Timer, Email operations
  • Modbus/TCP Protocol for SCADA Software Seamless Integration
  • IEEE 802.3af-compliant Power over Ethernet (PoE)
  • 10/100 Base-TX Ethernet
  • 2-way Isolation/ESD Protection
  • DO Type: 8 Isolated Open Collectors (Sink Type)
  • DI Type: 8 Isolation Wet Contact (Sink/Source)

WISE (Web Inside, Smart Engine) is a product series developed by ICP DAS that functions as control units for use in remote logic control and monitoring in various industrial applications. WISE offers a user-friendly and intuitive web site interface that allows users to implement IF-THEN-ELSE control logic on controllers just a few clicks away; no programming is required. With its powerful and easy-to-use features, it will minimize the learning curve, shorten time to market and dramatically reduce the labor and cost spent on system development. WISE-7144 follows IEEE 802.3af-compliant (classification, Class 1) Power over Ethernet (PoE) specification. It allows receiving power from PoE enabled network by Ethernet pairs (Category 5 Ethernet cable). This feature provides greater flexibility and higher efficiency therefore simplifying systems design, saving space, reducing cables and eliminating the requirement for dedicated electrical outlets. Meanwhile, in case under a non-PoE environment, WISE-7144 will still be able to receive power from auxiliary power sources like AC adapters or battery, etc. This module WISE-7144 supports Modbus/TCP protocol to make seamless integration with SCADA software available. It features 8-channel isolated open collector outputs and 8-channel isolated wet contact digital inputs. Each output channel supports 300mA current driving +10 ~ 40 VDC and each channel supports the counter function.

Digital Input

Input Channels: 8
Input Type: Wet Contact (Sink, Source)
On Voltage Level: +10 VDC ~ +50 VDC
Off Voltage Level: +4 VDC Max.
Input Impedance: 10 kΩ
Counters:
     Max. Count 65535 (16 bits)
     Max. Input Frequency: 50 Hz
     Min. Pulse Width: 10 ms
Overvoltage Protection: +70 VDC

Digital Output

Output Channels: 8
Output Type: Isolated Open Collector (Sink)
Max. Load Current: 300 mA/channel at 25 °CDirect drive power relay module
Output Voltage: +10 VDC ~ +40 VDC
Overvoltage Protection: 60 VDC
Overload Protection: 1.1 A
Short-circuit Protection: Yes

System

CPU: 16-bit CPU
SRAM: 512KB
Flash Memory: 512KB
EEPROM: 16KB
Watchdog: Yes

Communication

PoE Ethernet Port
10/100 Base-TX and automatic MDI/MDI-X

2-Way Isolation

I/O 3750 Vrms

EMS Protection

ESD (IEC 61000-4-2): 4 kV Contact for each terminal
EFT (IEC 61000-4-4): +/-2 kV for Power

LED Indicators

PoE Power PoE: On
L1: System Running
L2: Ethernet Link/Act
L3: Ethernet 10/100 M Speed

Power Requirements

Reverse Polarity Protection: Yes
Powered from Terminal Block: Yes, 12 ~ 48 VDC
Powered from PoE: Yes, IEEE 802.3af, Class1
Consumption: 4.3 W

Mechanical

Dimensions (W x L x D): 72 mm x 123 mm x 35 mm
Installation: DIN-Rail or Wall mounting

Environment

Operating Temperature: -25 °C ~ +75 °C
Storage Temperature: -30 °C ~ +80 °C
Humidity: 10 ~ 90% RH, non-condensingù

Functions

Rule Configuration Website: Access Web server on WISE controllers to edit and upload logic rules through web browser.
36 IF-THEN-ELSE Logic Rules: 
        3 IF conditions with AND or OR operators
        3 THEN actions and 3 ELSE actions
48 Internal Registers: Hold temporary variables and read/write data via Modbus/TCP address.
12 Timers: Delay / Timing functions.
12 Emails: Send Email messages to pre-set Email receivers.
12 CGI Commands: Send pre-set CGI commands.
12 Recipes: Set up THEN/ELSE action groups.
8 P2P remote modules: Set up the connection information for the remote WISE modules.
Modbus/TCP Protocol: Real time control and monitoring I/O channels and system status of controllers via SCADA software.

IF Conditions

DI Channel: ON、OFF、ON to OFF、OFF to ON、Change
Internal Register: =、>、<、>=、<=(value)
DI Counter - DO Counter: =、>、<、>=、<=(value)、Change
Timer: Timeout、Not Timeout
P2P: DI、AI、DI counter、DO counter、IR
Rule Status: Enable、Disable

THEN / ELSE Actions

DO Channel: ON、OFF、Pulse Output
Internal Register: Change the value
DI Counter - DO Counter: Reset
Timer: Start、Stop
Email - CGI Commands: Send
Recipe: Execute
P2P: DO(On/Off)、AO、IR
Rule Status: Enable、Disable