WISE-7119
8-channel Analog Input with High Voltage Protection and 4-channel Isolated Digital Output WISE PoE Controller (RoHS)
- Built-in Web Server for IF-THEN-ELSE rule setting
- Built-in IF-THEN-ELSE rule enigne for logic operation
- No more programming. Just click and get done!
- Support IO, Counter, Timer, Email operations
- Modbus/TCP Protocol for SCADA Software Seamless Integration
- IEEE 802.3af-compliant Power over Ethernet (PoE)
- 10/100 Base-TX Ethernet
- Support Current Input, Voltage Input and Thermocouple Input
- Over Voltage Protection is up to 240 Vrms
- 4-channel Digital Outputs
- 2-way Isolation/ESD Protection
WISE (Web Inside, Smart Engine) is a product series developed by ICP DAS that functions as control units for use in remote logic control and monitoring in various industrial applications. WISE offers a user-friendly and intuitive web site interface that allows users to implement IF-THEN-ELSE control logic on controllers just a few clicks away; no programming is required. With its powerful and easy-to-use features, it will minimize the learning curve, shorten time to market and dramatically reduce the labor and cost spent on system development. WISE-7119 follows IEEE 802.3af-compliant (classification, Class 1) Power over Ethernet (PoE) specification. It allows receiving power from PoE enabled network by Ethernet pairs (Category 5 Ethernet cable). This feature provides greater flexibility and higher efficiency therefore simplifying systems design, saving space, reducing cables and eliminating the requirement for dedicated electrical outlets. Meanwhile, in case under a non-PoE environment, WISE-7119 will still be able to receive power from auxiliary power sources like AC adapters or battery, etc. This multi-function module WISE-7119 supports Modbus/TCP protocol to make seamless integration with SCADA software available. It features 16-bit, 8-channel differential analog inputs and 4-channel digital ouputs. Each analog channel is allowed to configure an individual range and has 240 Vrms high over voltage protection
Analog Input
Input Channel: 8 (Differential)
Input Type (jumper selectable): +/-15 mV, +/-50 mV, +/-100 mV, +/-150 mV, +/-500 mV, +/-1 V, +/-5 V, +/-10 V +/-20 mA, 0 ~ 20 mA, 4 ~ 20 mA
Thermocouple (J, K, T, E, R, S, B, N, C, L, M, LDIN43710)
Resolution: 16-bit
Sampling Rate: 10 Sample/Sec. (Total)
Accuracy: +/-0.1% or better
Zero Drift: +/-10 μV/°C
Span Drift: +/-25 ppm/°C
Overvoltage Protection: 240 Vrms
Input Impedance:
Voltage: >1 MΩ
Current: 125 Ω
Common Mode Rejection: 86 dB Min.
Normal Mode Rejection: 100 dB
Individual Channel Configuration: Yes
Open Wire Detection: Yes
Digital Output
Output Channels: 4
Output Type Isolated Open Collector: (Sink)
Max. Load Current: 700 mA/Channel
Load Voltage: +5 VDC ~ +50 VDC
Overvoltage Protection: 60 VDC
Overload Protection: 1.4 A
Short-circuit Protection: Yes
System
CPU: 16-bit CPU
SRAM: 512KB
Flash Memory: 512KB
EEPROM: 16KB
Watchdog: Yes
Communication
PoE Ethernet Port
10/100 Base-TX and automatic MDI/MDI-X
2-Way Isolation
I/O 2500 VDC
EMS Protection
ESD (IEC 61000-4-2): 4 kV Contact for each terminal and 8 kV
Air for random point
EFT (IEC 61000-4-4): +/-4 kV for Power
LED Indicators
PoE Power PoE On
L1: System Running
L2: Ethernet Link/Act
L3: Ethernet 10/100 M Speed
Power Requirements
Reverse Polarity Protection: Yes
Powered from Terminal Block: Yes, 12 ~ 48 VDC
Powered from PoE: Yes, IEEE 802.3af, Class1
Consumption: 3.4 W
Mechanical
Dimensions (W x L x D): 72 mm x 123 mm x 35 mm
Installation: DIN-Rail or Wall mounting
Environment
Operating Temperature: -25 °C ~ +75 °C
Storage Temperature: -30 °C ~ +80 °C
Humidity: 10 ~ 90% RH, non-condensing
Functions
Rule Configuration Website: Access Web server on WISE controllers to edit and upload logic rules through web browser.
36 IF-THEN-ELSE Logic Rules:
3 IF conditions with AND or OR operators
3 THEN actions and 3 ELSE actions
48 Internal Registers: Hold temporary variables and read/write data via Modbus/TCP address.
12 Timers: Delay / Timing functions.
12 Emails: Send Email messages to pre-set Email receivers.
12 CGI Commands: Send pre-set CGI commands.
12 Recipes: Set up THEN/ELSE action groups.
8 P2P remote modules: Set up the connection information for the remote WISE modules.
Modbus/TCP Protocol: Real time control and monitoring I/O channels and system status of controllers via SCADA software.
IF Conditions
AI Channel - Internal Register: =、>、<、>=、<=(value)
DO Counter: =、>、<、>=、<=(value)、Change
Timer: Timeout、Not Timeout
P2P: DI、AI、DI counter、DO counter、IR
Rule Status: Enable、Disable
THEN / ELSE Actions
DO Channel: ON、OFF、Pulse Output
Internal - Register: Change the value
DO Counter: Reset
Timer: Start、Stop
Email - CGI Commands: Send
Recipe: Execute
P2P: DO(On/Off)、AO、IR
Rule Status: Enable、Disable