Benvenuti sulla nostra nuova piattaforma ICP DAS
Che sostituisce industrialtech.it

WISE-7115 ICP DAS

WISE-7115 ICP DAS

WISE-7115

7-channel RTD Input with 3-wire RTD lead resistance elimination WISE PoE Controller (RoHS)

Price

€ 406,78

(VAT excluded)

€ 496,27(VAT included)

Prezzo di 1 pz. iva (22%) inclusa: € 496,27

Availability: Not Available

SKU: 4439

Model: WISE-7115

Need Help?


  • Built-in Web Server for IF-THEN-ELSE rule setting
  • Built-in IF-THEN-ELSE rule enigne for logic operation
  • No more programming. Just click and get done!
  • Support IO, Counter, Timer, Email operations
  • Modbus/TCP Protocol for SCADA Software Seamless Integration
  • IEEE 802.3af-compliant Power over Ethernet (PoE)
  • 10/100 Base-TX Ethernet
  • AI Type: 7 RTD (Pt100, Pt1000, Ni120, Cu100, Cu1000)
  • Individual Channel Configuration
  • 3-wire RTD Input with Lead Resistance Elimination
  • 2-way Isolation/ESD Protection

WISE (Web Inside, Smart Engine) is a product series developed by ICP DAS that functions as control units for use in remote logic control and monitoring in various industrial applications. WISE offers a user-friendly and intuitive web site interface that allows users to implement IF-THEN-ELSE control logic on controllers just a few clicks away; no programming is required. With its powerful and easy-to-use features, it will minimize the learning curve, shorten time to market and dramatically reduce the labor and cost spent on system development. WISE-7115 follows IEEE 802.3af-compliant (classification, Class 1) Power over Ethernet (PoE) specification. It allows receiving power from PoE enabled network by Ethernet pairs (Category 5 Ethernet cable). This feature provides greater flexibility and higher efficiency therefore simplifying systems design, saving space, reducing cables and eliminating the requirement for dedicated electrical outlets. Meanwhile, in case under a non-PoE environment, WISE-7115 will still be able to receive power from auxiliary power sources like AC adapters or battery, etc. This WISE-7115 module supports Modbus/TCP protocol to make seamless integration with SCADA software available. It features 16-bit, 7-channel RTD inputs. Each channel is allowed to configure an individual range that supports 3-wire RTD lead resistance elimination and open wire detection for RTD measurement.

RTD Input

Input Channels: 7 (Differential)
Sensor Type: Pt100, Pt1000, Ni120, Cu100, Cu1000
Wire Connection: 2/3 Wire
Resolution: 16-bit
Sampling Rate: 12 Sample/Sec. (Total)
Accuracy: +/-0.05%
Zero Drift: +/-0.5 μV/°C
Span Drift: +/-20 μV/°C
Common Mode Rejection: 150 dB
Normal Mode Rejection: 100 dB
Input Impedance: >1MΩ
Open Wire Detection: Yes
Individual Channel Configuration: Yes
3-wire RTD Lead Resistance Elimination: Yes

System

CPU: 16-bit CPU
SRAM: 512KB
Flash Memory: 512KB
EEPROM: 16KB
Watchdog: Yes

Communication

PoE Ethernet Port
10/100 Base-TX and automatic MDI/MDI-X

2-Way Isolation

I/O 2500 VDC

EMS Protection

ESD (IEC 61000-4-2): 4 kV Contact for each terminal and 8 kV Air for random point
EFT (IEC 61000-4-4): +/-4 kV for Power

LED Indicators

PoE PoE: On
L1: System Running
L2: Ethernet Link/Act
L3: Ethernet 10/100 M Speed

Power Requirements

Reverse Polarity Protection: Yes
Powered from Terminal Block: Yes, 12 ~ 48 VDC
Powered from PoE: Yes, IEEE 802.3af, Class1
Consumption: 2.6 W

Mechanical

Dimensions (W x L x D): 72 mm x 123 mm x 35 mm
Installation: DIN-Rail or Wall mounting

Environment

Operating Temperature: -25 °C ~ +75 °C
Storage Temperature: -30 °C ~ +80 °C
Humidity: 10 ~ 90% RH, non-condensing

Functions

Rule Configuration Website: Access Web server on WISE controllers to edit and upload logic rules through web browser.
36 IF-THEN-ELSE Logic Rules: 
      3 IF conditions with AND or OR operators
      3 THEN actions and 3 ELSE actions
48 Internal Registers: Hold temporary variables and read/write data via Modbus/TCP address.
12 Timers: Delay / Timing functions.
12 Emails: Send Email messages to pre-set Email receivers.
12 CGI Commands: Send pre-set CGI commands.
12 Recipes: Set up THEN/ELSE action groups.
8 P2P remote modules: Set up the connection information for the remote WISE modules.
Modbus/TCP Protocol: Real time control and monitoring I/O channels and system status of controllers via SCADA software.

IF Conditions

AI Channel - Internal Register: =、>、<、>=、<=(value)
Timer: Timeout、Not Timeout
P2P DI、AI、DI counter、DO counter、IR
Rule Status: Enable、Disable

THEN / ELSE Actions

Internal - Register: Change the value
Timer: Start、Stop
Email - CGI Commands: Send
Recipe: Execute
P2P: DO(On/Off)、AO、IR
Rule Status: Enable、Disable