Benvenuti sulla nostra nuova piattaforma ICP DAS
Che sostituisce industrialtech.it

WISE-7150 ICP DAS

WISE-7150 ICP DAS

WISE-7150

6-channel Isolated Sink Type Open Collector Output and 12-channel Isolated Digital Input PoE Module (RoHS)

Price

€ 259,32

(VAT excluded)

€ 316,37(VAT included)

Prezzo di 1 pz. iva (22%) inclusa: € 316,37

Availability: Not Available

SKU: 110574

Model: WISE-7150

Need Help?


  • Built-in Web Server for IF-THEN-ELSE rule setting
  • Built-in IF-THEN-ELSE rule enigne for logic operation
  • No more programming. Just click and get done!
  • Support IO, Counter, Timer, Email operations
  • Modbus/TCP Protocol for SCADA Software Seamless Integration
  • IEEE 802.3af-compliant Power over Ethernet (PoE)
  • 10/100 Base-TX Ethernet
  • 2-way Isolation/ESD Protection
  • DO Type: 6 Isolated Open Collectors (Sink Type)
  • DI Type: 12 Isolation Wet Contact (Sink/Source)

Introduction

WISE (Web Inside, Smart Engine) is a product series developed by ICP DAS that functions as control units for use in remote logic control and monitoring in various industrial applications. WISE offers a user-friendly and intuitive web site interface that allows users to implement IF-THEN-ELSE control logic on controllers just a few clicks away; no programming is required. With its powerful and easy-to-use features, it will minimize the learning curve, shorten time to market and dramatically reduce the effort and cost spent on system development.
 
WISE-7150 follows IEEE 802.3af-compliant (classification, Class 1) Power over Ethernet (PoE) specification. It allows receiving power from PoE enabled network by Ethernet pairs (Category 5 Ethernet cable). This feature provides greater flexibility and higher efficiency therefore simplifying systems design, saving space, reducing cables and eliminating the requirement for dedicated electrical outlets. Meanwhile, in case under a non-PoE environment, WISE-7150 will still be able to receive power from auxiliary power sources like AC adapters or battery, etc.
 
This module WISE-7150 supports Modbus/TCP protocol to make seamless integration with SCADA software available. It features 6-channel isolated open collector outputs and 12-channel isolated wet contact digital inputs. Each output channel supports 100 mA currnet driving @ 5 ~ 30 VDC and each digital input channel supports counter input.

Applications

Building Automation, Factory Automation, Machine Automation, Remote Maintenance, Remote diagnosis and Testing Equipment, etc.

Hardware Specifications

Digital Input
Input Channels: 12
Input Type: Wet Contact (Sink, Source)
On Voltage Level: +10 VDC ~ +50 VDC
Off Voltage Level: +4 VDC Max.
Input Impedance: 10 kΩ
Counters: Max. Count 65535 (16 bits)
 Max. Input Frequency 50 Hz
 Min. Pulse Width 10 ms
 
Overvoltage Protection: +70 VDC
 
Digital Output
Output Channels: 6
Output Type: Open Collector (Sink)
Max. Load Current: 100 mA/channel at 25 °C
Output Voltage: +5 VDC ~ +30 VDC
Overvoltage Protection: 60 VDC
Overload Protection: 1.3A
Short-circuit Protection: Yes
 
System
CPU: 16-bit CPU
SRAM: 512 KB
Flash Memory: 512 KB
EEPROM: 16 KB
Watchdog: Yes
 
Communication
PoE Ethernet Port: 10 / 100 Base-TX and Automatic MDI/MDI-X
 
2 Way Isolation
I/O: 2500 VDC
 
EMS Protection
ESD (IEC 61000-4-2): ±4 kV Contact for each terminal and ±8 kV Air for random point
EFT (IEC 61000-4-4): ±4 kV for Power Line
 
LED Indicators
PoE: PoE On
L1: System Running
L2: Ethernet Link/Act
L3: Ethernet 10/100M Speed
 
Power Requirements
Reserve Polarity Protection: Yes
Powered from terminal block: Yes, 12 ~ 48 VDC
Powered from PoE: Yes, IEEE 802.3af, Class1
Consumption: 2.4 W
 
Mechanical
Dimensions (W x H x D): 72 mm x 123 mm x 35 mm
Installation: DIN-Rail or Wall mounting
 
Environment
Operating Temperature: -25 °C ~ +75 °C
Storage Temperature: -30 °C ~ +80 °C
Humidity: 10 ~ 90% RH, non-condensing

Software Specifications

Functions
Rule Configuration Website: Access Web server on WISE controllers to edit and upload logic rules through web browser.
36 IF-THEN-ELSE Logic Rules: 3 IF conditions with AND or OR operators

 3 THEN actions and 3 ELSE actions
 
48 Internal Registers: Hold temporary variables and read/write data via Modbus/TCP address.
12 Timers: Delay / Timing functions.
12 Emails: Send Email messages to pre-set Email receivers.
12 CGI Commands: Send pre-set CGI commands.
12 Recipes: Set up THEN/ELSE action groups.
8 P2P remote modules: Set up the connection information for the remote WISE modules.
Modbus/TCP Protocol: Real time control and monitoring I/O channels and system status of controllers via SCADA software.
 
IF Conditions
DI Channel: ON、OFF、ON to OFF、OFF to ON、Change
Internal Register: = 、> 、< 、 ≥ 、 ≤ (value)
DI Counter: = 、> 、< 、 ≥ 、 ≤ (value)、Change
DO Counter: = 、> 、< 、 ≥ 、 ≤ (value)、Change
Timer: Timeout、Not Timeout
P2P: DI、AI、DI counter、DO counter、IR
Rule Status: Enable、Disable
 
THEN / ELSE Actions
DO Channel: ON, OFF, Pulse Output
Internal Register: Change the value
DI Counter: Reset
DO Counter: Reset
Timer: Start、Stop
Email: Send
CGI Commands: Send
Recipe: Execute
P2P: DO(On/Off)、AO、IR
Rule Status: Enable、Disable

Disclaimer