Benvenuti sulla nostra nuova piattaforma ICP DAS
Che sostituisce industrialtech.it

PM-3033 ICP DAS

PM-3033 ICP DAS

PM-3033

Modbus RTU, 3-phase power meter (1A/5A CT Input type)

Price

€ 266,44

(VAT excluded)

€ 325,06(VAT included)

Prezzo di 1 pz. iva (22%) inclusa: € 325,06

Availability: Not Available

SKU: 106640

Model: PM-3033

Need Help?


ICP DAS brings the most powerful, cost-effective, advanced Smart Power Meters PM-3033 series that gives you access to real-time electric usage for three-phase power measurement. With its high accuracy (<0.5%, PF=1 ), the PM-3033 series can be applied to both low voltage primary side and/or medium/high voltage secondary side and enables the users to obtain reliable and accurate energy consumption readings from the monitored equipments in real time under operation.
Direct input from “secondary side 1A/5A” type CTs. Dedicated CTs are no longer needed, which lowers the cost of implementation. It operates over a wide input voltages range 10 ~ 500 VAC which allows worldwide compatibility. It also supports Modbus RTU, Modbus TCP or CANopen protocols for easy integration.
PM-3033: Modbus RTU, 3-phase power meter (1A/5A CT Input type)

  • True RMS Power Measurements
  • Energy Analysis for 3P4W, 3P3W, 1P3W, 1P2W
  • Direct input of secondary side 1A/5A CT
  • Voltage Measurements Up to 500 V
  • W Accuracy Better than 0.5% (PF=1)
  • Supports RS-485, Ethernet (PoE) or CANopen Interface
  • Supports Modbus RTU, Modbus TCP or CANopen Protocol
  • Total Harmonic Distortion (THD)
  • IEC 61010-1 and EN 61010-1

AC Power Measurement

Wiring: 3P4W-3CT, 3P3W-2CT, 3P3W-3CT, 1P2W-1CT, 1P3W-2CT
Measurement Voltage: 10 ~ 500 V
Measurement Current: 1A or 5A
Measurement Frequency: 50/60 Hz
W Accuracy: Better than 0.5% (PF=1)
Power Parameter Measurement: True RMS voltage (Vrms), True RMS current (Irms), Active Power (kW), Active Energy (kWh), Apparent Power (kVA), Apparent Energy (kVAh), Reactive Power (kVAR), Reactive Energy (kVARh), Power Factor (PF), Frequency
Data Update Rate: 1 Second

Communication

RS-485

  • Protocol: Modbus-RTU
  • Baud rate: 9600,19200 (default), 38400, 115200;
  • DIP Switch Selectable
  • Data format: N,8,1 (default); N,8,2; E,8,1; E,8,2; O,8,1; O,8,2
  • Isolation: 3000 VDC

Ethernet (PoE)

  • Protocol: -

CANopen

  • Protocol: -
  • Baud rate: -
  • Isolation: -

Power

Input Range: +12 ~ 48 VDC
Power Consumption: 2 W

Mechanical

Casing: Plastic
Dimensions (W x L x H): 127 mm x 105 mm x 33 mm
Module Installation: DIN-Rail Mounting

Environment

Operating Temperature: -20 ~ +70 °C
Storage Temperature: -25 ~ +80 °C
Ambient Relative Humidity: 10% ~ 90% RH, Non-condensing

Disclaimer