XV308 CR
8-ch Isolated Analog input and 8-ch Isolated Universal Digital I/O Expansion Board
The XV308 provides 8 channels for analog input and 8 channels for universal digital input/output. Analog Input channels are Single-ended type and provide a programmable input range (±1 V, ±2.5 V, ±5 V, ±10 V, ±20 mA, 0 ~ 20 mA, 4 ~ 20 mA). Each Analog Input channels also provides a high overvoltage protection of 120 VDC. Universal digital input/output can be selected via wire connections. Digital input channels are sourcetype and can be used as 32-bit counters. Digital output channels are sink-type with short circuit protection and options for configuring power-on digital output values.
XV308 CR: 8-channel Isolated Analog Input and 8-channel Isolated Universal Digital Input/Output Expansion Board (RoHS)
- 8-channel Analog Input
- 8-channel Universal Digital Input/Output
- Digital Input Channels can be used as 32-bit Counters
- Configurable Power-on Value Settings
- Open Wire Detection for 4 ~ 20 mA
- Individual Channel Configuration
- 120 VDC Overvoltage Protection for Analog Input
- 60 VDC Overvoltage Protection for Digital Input
- Overload Protection for Digital Output
- Short-circuit Protection for Digital Output
Analog Input
Channels: 8
Type: ±1 V, ±2.5 V, ±5 V, ±10 V, ±20 mA, 0 ~ 20 mA, 4 ~ 20 mA (Jumper Selectable)
Resolution: 16-bit
Sampling Rate: Normal Mode 10 Hz ; Fast Mode 200 Hz
Accuracy: Normal Mode ±0.1 % ; Fast Mode ±0.5 %
Input Impedance: 20 MΩ
Overvoltage Protection: 120 VDC
Universal Digital Input/Output
Channels: Digital Input and Digital Output=8 (By Wire Connection)
Digital Input
- Wet Contact:
- On Voltage Level +1 VDC Max
- Off Voltage Level +4 ~ 30 VDC
- Dry Contact:
- On Voltage Level: Close to GND
- Off Voltage Level Open
- Counters:
- Max. Count 32-bit (0~4,294,967,285)
- Max. Input Frequency 50 Hz
- Min. Pulse Width 10 ms
Overvoltage Protection 60 VDC
Digital Output
- Output Type Sink
- Max. Load Current 700 mA
- Load Voltage 3.5 ~ 50 VDC
- Overvoltage Protection 60 VDC
- Overload Protection Yes
- Short Circuit Protection Yes
- Power-on Value Yes, Programmable
Communication
Interface: RS-232/TTL
Format: N, 8, 1
Baud Rate: 115200 bps
Protocol: Modbus/RTU
Isolation
Intra-module Isolation, Field-to-Logic: 2000 VDC
EMS Protection
ESD (IEC 61000-4-2): ±4kV Contact For Each Terminal ; ±8kV Air For Random Terminal
Power
Powered from Terminal Block: 5 VDC
Consumption: 0.8 W Max.
Mechanical
Dimensions (W x L x H): 59 mm x 82 mm x 13 mm
Environment
Operating Temperature: -25 ~ +75°C
Storage Temperature: -30 ~ +80°C
Humidity: 10 to 90% RH, Non-condensing