  • Built-in Web Server for IF-THEN-ELSE rule setting
  • Built-in IF-THEN-ELSE rule enigne for logic operation
  • No more programming. Just click and get done!
  • Support IO, Counter, Timer, Email operations
  • Modbus/TCP Protocol for SCADA Software Seamless Integration
  • IEEE 802.3af-compliant Power over Ethernet (PoE)
  • 10/100 Base-TX Ethernet
  • 2-way Isolation/ESD Protection
  • DI Type: 16 Dry Contact

Introduction

WISE (Web Inside, Smart Engine) is a product series developed by ICP DAS that functions as control units for use in remote logic control and monitoring in various industrial applications. WISE offers a user-friendly and intuitive web site interface that allows users to implement IF-THEN-ELSE control logic on controllers just a few clicks away; no programming is required. With its powerful and easy-to-use features, it will minimize the learning curve, shorten time to market and dramatically reduce the effort and cost spent on system development.
 
WISE-7153 follows IEEE 802.3af-compliant (classification, Class 1) Power over Ethernet (PoE) specification. It allows receiving power from PoE enabled network by Ethernet pairs (Category 5 Ethernet cable). This feature provides greater flexibility and higher efficiency therefore simplifying systems design, saving space, reducing cables and eliminating the requirement for dedicated electrical outlets. Meanwhile, in case under a non-PoE environment, WISE-7153 will still be able to receive power from auxiliary power sources like AC adapters or battery, etc.
 
This module WISE-7153 supports Modbus/TCP protocol to make seamless integration with SCADA software available. It features 16-channel dry contact digital inputs. Each digital input channel supports counter input.

Applications

Building Automation, Factory Automation, Machine Automation, Remote Maintenance, Remote diagnosis and Testing Equipment, etc.

Hardware Specifications

Digital Input
Input Channels: 16
Input Type: Dry Contact (Source)
On Voltage Level: Close to GND
Off Voltage Level: Open
Counters: Max. Count 65535 (16 bits)
 Max. Input Frequency 50 Hz
 Min. Pulse Width 10 ms
 
System
CPU: 16-bit CPU
SRAM: 512 KB
Flash Memory: 512 KB
EEPROM: 16 KB
Watchdog: Yes
 
Communication
PoE Ethernet Port: 10 / 100 Base-TX and Automatic MDI/MDI-X
 
2 Way Isolation
I/O: 2500 VDC
 
EMS Protection
ESD (IEC 61000-4-2): ±4 kV Contact for each terminal and ±8 kV Air for random point
EFT (IEC 61000-4-4): ±2 kV for Power Line
 
LED Indicators
PoE: PoE On
L1: System Running
L2: Ethernet Link/Act
L3: Ethernet 10/100M Speed
 
Power Requirements
Reserve Polarity Protection: Yes
Powered from terminal block: Yes, 12 ~ 48 VDC
Powered from PoE: Yes, IEEE 802.3af, Class1
Consumption: 3.0 W
 
Mechanical
Dimensions (W x H x D): 72 mm x 123 mm x 35 mm
Installation: DIN-Rail or Wall mounting
 
Environment
Operating Temperature: -25 °C ~ +75 °C
Storage Temperature: -30 °C ~ +80 °C
Humidity: 10 ~ 90% RH, non-condensing

Software Specifications

Functions
Rule Configuration Website: Access Web server on WISE controllers to edit and upload logic rules through web browser.
36 IF-THEN-ELSE Logic Rules: 3 IF conditions with AND or OR operators

 3 THEN actions and 3 ELSE actions
 
48 Internal Registers: Hold temporary variables and read/write data via Modbus/TCP address.
12 Timers: Delay / Timing functions.
12 Emails: Send Email messages to pre-set Email receivers.
12 CGI Commands: Send pre-set CGI commands.
12 Recipes: Set up THEN/ELSE action groups.
8 P2P remote modules: Set up the connection information for the remote WISE modules.
Modbus/TCP Protocol: Real time control and monitoring I/O channels and system status of controllers via SCADA software.
 
IF Conditions
DI Channel: ON、OFF、ON to OFF、OFF to ON、Change
Internal Register: = 、> 、< 、 ≥ 、 ≤ (value)
DI Counter: = 、> 、< 、 ≥ 、 ≤ (value)、Change
Timer: Timeout、Not Timeout
P2P: DI、AI、DI counter、DO counter、IR
Rule Status: Enable、Disable
 
THEN / ELSE Actions
Internal Register: Change the value
DI Counter: Reset
Timer: Start, Reset
Email: Send
CGI Commands: Send
Recipe: Execute
P2P: DO(On/Off)、AO、IR
Rule Status: Enable、Disable