WISE-5801 ICP DAS

WISE-5801 ICP DAS

WISE-5801

User-defined I/O & Data Logger Module with SMS Function

Price

€ 610,16

(VAT excluded)

€ 744,40(VAT included)

Prezzo di 1 pz. iva (22%) inclusa: € 744,40

Availability: Not Available

SKU: 92896

Model: WISE-5801

Need Help?


  • Built-in Web Server for IF-THEN-ELSE rule setting
  • Built-in IF-THEN-ELSE rule enigne for logic operation
  • Support IO, Counter, Timer, Schedule, Email, Recipe operations
  • No more programming. Just click and get done!
  • Data logger and data files send back function supported
  • Modbus TCP/RTU Protocol for SCADA Software Seamless
  • 10/100 Base-TX Ethernet
  • Support XW-Board
  • Support I-7000 Remote I/O Modules (Up to 16)
  • Support Modbus RTU Slave Devices (Up to 10)
  • SNTP Time Synchronization Supported
  • Support SMS (GSM: Quad-band 850/900/1800/1900 MHz)

INTRODUCTION

WISE (Web Inside, Smart Engine) is a product series developed by ICP DAS that functions as control units for use in remote logic control and monitoring in various industrial applications. WISE offers a user-friendly and intuitive web site interface that allows users to implement IF-THEN-ELSE control logic on controllers just a few clicks away; no programming is required. With its powerful and easy-to-use features, it will minimize the learning curve, shorten time to market and dramatically reduce the effort and cost spent on system development.
 
WISE-5801 supports an I/O expansion bus to implement various I/O functions such as D/I, D/O, A/D and D/A according to the XW-Board. In addition, it also support ICP DAS I-7000 / M-7000 remote I/O modules and Modbus RTU slave devices. Based on the variety I/O module of I-7000 / M-7000 and the connection ability with Modbus RTU slave devices, WISE-5801 can provide user more flexibility in application field.
 
WISE-5801 supports Modbus TCP/RTU protocol to make seamless integration with SCADA software available. It include all advantages which WISE series controllers can provide. In addition, WISE-5801 provide data logger function with microSD card, it can record I/O channel value by event trigger or regular time period. The data files can be sent back by Email or FTP. All setting can be completed through browser.
 
In addition to merits inherited from the existing WISE series, WISE-5801 even provides more supports in I/O functions. It allows to connecting with a wide range of XW-Boards, I-7000 / M-7000 Remote I/O modules and Modbus RTU slave devices that enables users to freely choose the most suitable I/O modules. With the microSD card, it provides Data Logger function to real-time record the I/O data of the controller and send the data files by FTP or Email at a scheduled time to the control center for further administration management or data analysis. WISE-5801 also features SMS sending function for alarm report and SMS command receiving function.

Hardware Specifications

CPU Module
CPU: 16-bit CPU
SRAM: 768 KB
Flash: 512 KB
microSD Expansion: Support up to 32 GB microSDHC card
RTC (Real Time Clock): RTC Provide seconds, minutes, hours, date of week/month; month and year
Watchdog Timers: Yes (0.8 second)
 
Communication Ports
Ethernet: RJ-45 x 1, 10/100 Base-TX (Auto-negotiating, Auto MDI/MDI-X, LED indicators)
COM 1: RS-232 (TxD, RxD, RTS, CTS, GND), non-isolated, Speed: 115200 bps max.
COM 2: RS-485 (D2+, D2-), self-tuner ASIC inside, non-isolated, Speed: 115200 bps max.
 
LED Indicators
System LED: Yes (Red)
Ethernet Link LED: Yes (Green: Ethernet link detected, Flashing Green: Ethernet packet received)
 
Hardware Expansion
I/O Expansion Bus: Yes
 
SMS Function
Frequency Band: Quad-band 850/900/1800/1900 MHz
Mode: Text and Unicode mode
 
Power Requirements
Protection: Power Reverse Polarity Protection
Frame Ground: Yes (for ESD Protection)
Input Range: 12 ~ 48 VDC
Redundant Power Input: Yes
Power Consumption: 2.0 W
 
Mechanical
Dimensions (W x H x D): 91 mm x 132 mm x 52 mm
Installation: DIN-Rail
 
Environment
Operating Temperature: -25 ~ +75 °C
Storage Temperature: -30 ~ +80 °C
Ambient Relative Humidity: 10 ~ 90% RH (non-condensing)

Software Specifications

Functions
Rule Configuration Website: Access Web server on WISE controllers to edit and upload logic rules through web browser.
36 IF-THEN-ELSE Logic Rules: 3 IF conditions with AND or OR operators

 3 THEN actions and 3 ELSE actions
 
48 Internal Registers: Hold temporary variables and read/write data via Modbus/TCP address.
12 Timers: Delay / Timing functions.
12 Schedules: Setup prescheduled routine tasks.
12 Emails: Send Email messages to pre-set Email receivers.
12 SMS: Send SMS to pre-set mobile phone numbers.
12 CGI Commands: Send pre-set CGI commands.
12 Recipes: Set up THEN/ELSE action groups.
Data Logger: Set up the Data Logger configuration, include the data record format, and data file sending operation.
Modbus TCP/RTU Protocol: Real time control and monitoring I/O channels and system status of controllers via SCADA software.
 
IF Conditions
DI Channel: ON、OFF、ON to OFF、OFF to ON、Change
AI Channel: = 、> 、< 、 ≥ 、 ≤ (value)
Internal Register:
DI Counter: = 、> 、< 、 ≥ 、 ≤ (value)、Change
Timer: Timeout、Not Timeout
Schedule: In Range、Out of Range
SMS Command: 0、1
Rule Status: Enable、Disable
 
THEN / ELSE Actions
DO Channel: ON、OFF、Pulse Output (apply to XW-Board only)
AO Channel: Change the value
Internal Register: Change the value
DI Counter: Reset
Timer: Start、Reset
Schedule: Enable、Disable
Email: Send
SMS Alarm: Send
CGI Commands: Send
Recipe: Execute
Data Logger: Start、Stop、One-Time Log
Rule Status: Enable、Disable