WISE-4000D
3-channel Digital Input, 3-channel Digital Output, and 8-channel Analog Input WISE PoE Controller (RoHS) with GPRS Module with LCD Display
- Built-in Web Server for IF-THEN-ELSE rule setting
- Built-in IF-THEN-ELSE rule enigne for logic operation
- No more programming. Just click and get done!
- Support IO, Counter, Timer, Email operations
- Modbus/TCP Protocol for SCADA Software Seamless Integration
- 10/100 Base-TX Ethernet
- Support GSM: Quad-band 850/900/1800/1900 MHz
- I/O: 3 channels DI, 3 channels DO, 8 channels AI
- 128*64 dots LCM display (only for WISE-4000D)
WISE (Web Inside, Smart Engine) is a product series developed by ICP DAS that functions as control units for use in remote logic control and monitoring in various industrial applications. WISE offers a user-friendly and intuitive web site interface that allows users to implement IF-THEN-ELSE control logic on controllers just a few clicks away; no programming is required. With its powerful and easy-to-use features, it will minimize the learning curve, shorten time to market and dramatically reduce the effort and cost spent on system development.
The WISE-4000 is an embedded controller that is perfect for use in real-time industrial equipment monitoring and environment monitoring. It allows updated status information being sent to the backend monitoring system via Ethernet interface. WISE-4000 supports Modbus/TCP protocol that allows seamless integration with SCADA software. It features 3 digital inputs, 3 digital outputs and 8 analog inputs. WISE-4000 also features SMS sending function for alarm report. By integrating with IF-THEN-ELSE rule engine, WISE-4000 even provides more powerful functions such as Schedule Send SMS Send e-mail Timer & I/O operation for use in various industrial applications.
Digital Input
Input Channels: 3
nput Type Source(Dry Type), Common Ground
On Voltage Level: +3.5 VDC ~ +30 VDC
Off Voltage Level: +1 VDC Max.
Isolated Voltage: Non-isolated
Counters Max. Count 65535 (16 bits)
Max. Input Frequency: 50 Hz
Min. Pulse Width: 10 ms
Digital Output
Output Channels: 3
Output Type: Open Collector (Sink/NPN)
Load Voltage: +30 VDC Max.
Load Current: 100 mA Max.
Isolated Voltage: Non-isolated
Counters Max. Count 65535 (16 bits)
Max. Input Frequency: 50 Hz
Min. Pulse Width: 10 ms
Analog Input
Input Channels: 8
Input Range/Type: 0~20 mA
Resolution: 12-bit
Sampling Rate: 1 KHz max. (Read one channel)
Model WISE-4000 - WISE-4000D
System
CPU: 16-bit CPU
SRAM/Flash: 512K/512K, real time clock, watchdog timer
NVRAM: 31 bytes
EEPROM: 16 KB
RTC (Real Time Clock): RTC Provide seconds, minutes, hours, date of week/month; month and year, valid from 1980 to 2079
Communication Interface
COM ports No (Unsupported by WISE firmware)
Ethernet 10/100 Base-TX Ethernet controller
SMS Function
Frequency Band Quad-band 850/900/1800/1900 MHz
Mode: Text and Unicode mode
LCD Interface
General:
Effective Display Area: 80.61 mm x 14.37 mm (W x H)
Module Dimension: 93 mm x 70 mm x 1.6 mm (W x H x T)
Life Time:
Expected life is more
than 100,000 hours
under normal operation
Power
Protection: Power reverse polarity protection
Frame Ground Protection: ESD, Surge, EFT, Hi-Pot
Power Requirement: 15W; Unregulated +10 VDC ~ +30 VDC
Power Consumption:
Idle: 75 mA @ 24 VDC;
Data Link: 150 ~ 400 mA (peak) @ 24 VDC
LED Indicators
System: Red
Mechanical
Dimensions: 72 mm x 123 mm x 35 mm (W x H x D)
Installation: DIN-Rail or Wall mounting
Environment
Operating Temperature: -15 °C ~ +55 °C
Storage Temperature: -20 °C ~ +70 °C
Humidity: 5~90% RH, non-condensing
Functions
Rule Configuration Website Access Web server on WISE controllers to edit and upload logic rules through web browser.
36 IF-THEN-ELSE Logic Rules:
3 IF conditions with AND or OR operators
3 THEN actions and 3 ELSE actions
48 Internal Registers Hold temporary variables and read/write data via Modbus/TCP address.
12 Timers Delay / Timing functions.
12 Schedules Setup prescheduled routine tasks.
12 SMS Send SMS to pre-set mobile phone numbers.
12 Emails Send Email messages to pre-set Email receivers.
12 CGI Commands Send pre-set CGI commands.
12 Recipes Set up THEN/ELSE action groups.
8 P2P remote modules Set up the connection information for the remote WISE modules.
Modbus/TCP Protocol Real time control and monitoring I/O channels and system status of controllers via SCADA software
IF Conditions
DI Channel: ON、OFF、ON to OFF、OFF to ON、Change
AI Channel - Internal Register: =、>、<、>=、<=(value)
DI Counter - DO Counter: =、>、<、>=、<=(value)、Change
Timer: Timeout、Not Timeout
Schedule: In Range、Out of Range
P2P: DI、AI、DI counter、DO counter、IR
Rule Status: Enable、Disable
THEN / ELSE Actions
DO Channel: ON、OFF、Pulse Output
Internal Register: Change the value
DI Counter - DO Counter: Reset
Timer Schedule: Start、Stop
SMS Email - CGI Commands: Send
Recipe: Execute
P2P: DO(On/Off)、AO、IR
Rule Status: Enable、Disable