Benvenuti sulla nostra nuova piattaforma ICP DAS
Che sostituisce industrialtech.it

FR-2054T ICP DAS

FR-2054T ICP DAS

FR-2054T

8-channel isolated digital output and 8-channel isolated digital input module

Price

€ 200,34

(VAT excluded)

€ 244,41(VAT included)

Prezzo di 1 pz. iva (22%) inclusa: € 244,41

Availability: Not Available

SKU: 3983

Model: FR-2054T

Need Help?


  • Built-in Wire-saving FRnet DI/DO control
  • High-speed transmission reliability
  • Simple synchronization mechanism
  • No software overhead on protocol processing
  • Supporting broadcasting (1:n data transmission)
  • Duplicating output easily
  • Fixed I/O scan-time and I/O synchronization
  • DIN-Rail

The FR-2054T has 8-channel isolated Sink/Source input and 8-channel isolated sink output. The FR-2000 I/O module has an FRnet interface. The users can daisy chain several FR-2000 modules together. Via FRnet, the FR-200 modules can extend the remote I/O control of PC, PAC and PLC easily. Further information about the networking of FR-2054T; refer to literature related to I-7188EF, I-8172/I-8172W, FRB-100/200/200U.

Digital Output

Output Channel: 8
Output Type: Sink, Open-Collector (NPN)
Load Voltage: 30 VDC, Max.
Load Current: 250mA, Max.
Isolation Voltage: 3750 Vrms

Digital Input

Input Channel: 8 (Sink/Source)
Input Type: Isolation, One Common for All Digital Inputs
On Voltage Level: +19 VDC ~ 30 VDC
Off Voltage Level: +11 VDC max
Input Impedance: 3.3 kOhm
Isolation Voltage: 3750 Vrms

Interface

2-wire cabling: 
      2-wire cabling Belden 9841 (2P twisted-pair cable),
      When different cables are used, the transmission distance may change
Transfer distance: 
      Max. 400m for speed 250Kbps
      Max. 100m for speed 1Mbps(Default)
LED Indicators: Power, Communication Run, Communication Error, Terminal resistor, Digital input/output
Transfer speed: 
      250Kbps and 1Mbps(Default)
      DIP Switch Settings
Cyclic scan time: 
      2.88ms for speed 250Kbps
      0.72ms for speed 1Mbps(Default)
Connection: Removable 20-pin Terminal Block

Power

Input Voltage Range: +10 ~ +30 VDC (Non-isolation)
Power consumption: 2W Max
Protection: Power reverse polarity protection
Frame Ground for EMS Protection: Yes
Connection: 5-Pin Removable Terminal Block

Mechanical

Casing: Plastic (Flammability UL 94V-0)
Dimensions (W x L x H): 33 mm x 102 mm x 110 mm
Installation: DIN-Rail

Mechanical

Operating Temperature: -25°C ~ +75°C
Storage Temperature: -30°C ~ +85°C
Ambient Relative Humidity: 10% ~ 90% RH, non-condensing